Owner’s ManualKenmore305 and 505 ModelsDirect Vent Tankless Water HeatersFOR OUTDOOR APPLICATIONS ONLYMODEL NO.154.330040154.330050154.330080154.33009
INSTALLATION INSTRUCTIONSOnly properly trained and qualified installers should install this appliance. The warranty may be voided due to improper inst
Table 1:to Combustibles to Non-CombustiblesBack of Heater0 (zero) 0 (zero)Front of 24 inches 24 inchesHeater (610 mm) (610 mm)Sides of 6 inches 1/8 i
Pipe Sizing Procedure - ExampleThe gas supply must be capable of handling the entire gas load at the location. Gas line sizing is based on gas
WATER PIPINGGeneral Instructions• A manual water control valve must be placed in the water inlet connection to the water heater befor
Figure 4: Freeze Protection Piping - DrawingVacuumBreakerKEYI il3/4" Ball ValvesPressure Regulator3/4" UnionCirculating PumpCheck ValveBoile
Figure 5: Recommended Piping for Basic InstallationFor Building FixturesKEYI 3/4" Ball Valve 3/4" Union Check Valve Pressure Relief ValvePre
Figure 6: Recommended Piping for Circulation Systems^_____I °o n o'^ I______f oNOTE:Applications, using this piping arrangement maintains fuli wa
Figure 7: Optional Piping for Circulation SystemsNOTE:Applications, using this piping arrangement reduces the warranty to the following:3 years on hea
VENTING INSTRUCTIONSRef Description US InstallationsA Clearance above grade, veranda, porch, deck, or balcony 12 inches (30 cm)B Clearance to window o
Additional Clearance - Vent TerminalLocal codes supersede these clearances.• Avoid termination locations near a dryer vent.• Avoid termination locat
SAFE INSTALLATION, USE AND SERVICEYour safety and the safety of others is extremely important in the installation, use and servicing of this water hea
HIGH ALTITUDE INSTALLATIONSSet dip switches 2 and 3 to the values shown in table below for your altitude. The default setting for the appliance is 0-2
TEMPERATURE CONTROLLER INSTALLATIONLocation Mounting the ControllerOutdoor models are supplied with one remote control unit. Additional controllers ca
DESCRIPTION OF OPERATIONThis appliance is one of the most advanced water heaters available. It provides a continuous supply of hot water at a preset t
TEMPERATURE ADJUSTMENTÀDANGERWater temperature over 125°F (52°C) can cause servere burns instantly resulting in severe injury or death.Children, the e
Temperature Options without a Temperature ControllerA WARNINGDo not adjust the other dip switches uniess specificaiiy instructed to do so.The default
OPERATING YOUR WATER HEATERFOR YOUR SAFETY READ BEFORE OPERATINGA WARNINGIf you do not follow these instructions exactly, a fire or explosion may resu
MAINTENANCEA WARNINGTurn off the electrical power supply, the manual gas valve and the manual water control valve whenever servicing the unit.Lime / S
TROUBLESHOOTINGThis appliance has the ability to check its own operation continuously. If a fault occurs, an error code will flash on the Display of t
Code Fault Remedy14Thermal Fuse Check gas type of unit and ensure it matches gas type being used.Check for restrictions in air flow around unit and ve
Troubleshooting for Common IssueAccessing Operating InformationI don’t have any hot water when I open the tap.Make sure there is gas, water, and elect
Safety Behavior and PracticesA WARNINGKeep the area around the appliance clear and free from combustible materials, gasoline, and other flammable vapo
Flushing the Heat Exchanger (Error Code: LC or 00)An “LC” or “00” error code indicates the unit is beginning to lime up and must be flushed. Failure t
WIRING DIAGRAMHOTNEUTRAL305 & 505 Outdoor Manual31
SERVICE AND ADJUSTMENTContact Sears Service Center at: 1-800-4-MY-HOME® (1-800-469-4663).For the convenience of the Qualified Service Technician a Tec
305 & 505 Outdoor Manual33
34305 & 505 Outdoor Manual
305 & 505 Outdoor Manual35
Get it fixed, at your home or ours!Your HomeFor expert troubleshooting and home solutions advice:www.managemyhome.comFor repair - in your home - of al
TABLE OF CONTENTSSafe Installation, Use and Service...2Safety Precautions...
PRODUCT WARRANTY12 Year Limited Warranty on Heat ExchangerFor 12 years from the date of purchase, if this water heater is installed and operated in a
CUSTOMER RESPONSIBILITIESThank You for purchasing a Kenmore water heater. Properly installed and maintained, it should give you years of troubl
PRODUCT SPECIFICATIONSMODEL305 Models 505 Models154.330040 & 154.330050 154.330080 & 154.330090Minimum gas consumption btu/h 15,000Maximum gas
DIMENSIONSDIM DESCRIPTION305 Series in. (mm)505 Series in. (mm)A Width 14 (355.6) 14 (355.6)B Depth * 9.8 (249.5) 9.8 (249.5)C Height - Unit 22.9 (582
TECHNICAL DATAPressure Drop CurveV)wwo_lCD13CDCDCD1009080706050403020100T3CDCDJZCDCDo_lCDU.13COCO0Outlet Flow Datadelta T - Temperature Rise (°F)305 &